Spectra Cinespot One-Degree Spotmeter
Designed
for Measuring Screen Brightness |
|
|
|
|
INTRODUCTION:
Spectra CineSpot Spotmeter
is exclusively designed to measure screen brightness
and uniformity in theaters, review rooms. CineSpot
has received one of the highest awards from the
Academy of Motion Picture Arts and Sciences
The economical, compact CineSpot 1˚
Spotmeter from SPECTRA CINE has been
designed for easy use and for making simple yet accurate
screen brightness measurements and other field
measurements. The CineSpot features eye-level,
magnified, thru-the-lens viewing of the 1-degree spot
area in a large (21-degree diagonal) rectangular
viewing field, with simultaneous display of the meter
reading superimposed in the viewing field.
For accuracy, each individually
calibrated instruments uses an ultra-stable silicon
photodetector, together with computer-selected glass
filters that match the spectral response of the human
eye. Readability of the CineSpot extends
from 0.5 to 300 foot-lamberts (30,000 footLamberts with
accessory 100X Attenuator), with excellent resolution
in the critical 10 to 30 foot-lambert region.
Back to Top ^ |
SPECIFICATIONS:
-
MEASURING CAPABILITY:
Luminance (Specify choice of
units : footLamberts or candelas/sq. meter).
-
SENSITIVITY: Low Range, 0 to 30
footLamberts (0 to 100 cd/m2 on metric version)
readings legible to 0.5 footLamberts. High Range, 0 to
300 footLamberts (0 to 1,000 cd/m2 on metric version);
accessory 10X and 100X Attenuators increase upper
limit to 3,000 or 30,000 footLamberts (10,000 or
100,000 cd/m2).
-
ANGULAR COVERAGE:
The CineSpot features eye-level, magnified,
thru-the-lens viewing of the 1-degree spot area in a
large (21-degree diagonal) rectangular viewing field,
with simultaneous display of the meter reading
superimposed in the viewing field.
-
FOCUSING dISTANCE:
Fixed- focus, 4 feet (1.2 m) to infinity; usable from
1 foot (0.3 m) to infinity.
-
VIEWING OPTICS :
1.6 X magnification, erect system with focusing
eyepiece; illuminated scale for low-light readability.
-
PHOTODETECTOR :
Ultra-stable Silicon Photovoltaic Cell.
-
SPECTRAL RESPONSE :
Matched to the human eye response (CIE 1931 photopic
luminosity function), using computer-selected glass
filters.
-
ACCURACY : Plus or
Minus 1% of full scale or 5% of reading, which ever is
greater, when measuring blackbody sources; traceable
to the (NIST) National Institute Of Standards
Technology.
-
CARRYING CASE:
Supplied in attractive, sturdy
foam-lined protective carrying case with space for
accessories.
-
warranty : One
year limited warranty.
-
Supplied WITH: Spectra
CineSpot spotmeter are supplied with a carrying case,
battery, instructional manual and warranty card.
Back to Top ^ |
ACCESSORIES:
-
Reflectance Standard Model RS-1-600
The CineSpot can accurately measure the integrated
(cosine Corrected) illuminance falling on any surface -
such as screen, desktop or workbench - with the aid of
the Reflectance Standard.
Automatic mechanical rolex replica watches are the development of manual mechanical watches, so have the basic elements of manual mechanical replica rolex watches. The automatic mechanical rolex replica watches has a function of full idling, which means that the automatic swiss replica watches will not break no matter how much the crown is twisted.
-
Neutral Density 10X Attenuator Model ND-1-600
These calibrated, Screw-in Neutral Density Filters
increase the upper measuring limit of the CineSpot. The
10X Attenuator provides a 10-times increase, while the
100X Attenuator provides a 100-times increase.